ColdChase™ Sensor Series
BLE Sensors
Our Bluetooth Low Energy (BLE) Sensors are power-efficient and rechargeable for long shipment activities. Paired with Gateway hardware or mobile connection, BLE sensors enable powerful monitoring capabilities.
T-BLE Sensor

Temperature Range | NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C |
GPS | Gateway communicator app or Gateway hardware |
Temperature Range
NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
S-BLE Sensor

Temperature Range | NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Shock | Up to 8g ±3% |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C | Light | Measured in lumens |
GPS | Gateway communicator app or Gateway hardware | Humidity | ±3% RH from 0 to 100% |
Temperature Range
NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
GPS
Gateway communicator app or Gateway hardware
Barometric Pressure
300 – 1100 hPa (mbar)
Shock
Up to 8g ±3%
Light
Measured in lumens
Humidity
±3% RH from 0 to 100%
Cellular Sensors
ColdChase™ cellular sensors provide an option of GEO or GPS tracking without the Gateway connection. With built-in airplane mode, tracking air cargo is safer and easier.
S-GEOCell Sensor

Temperature Range | NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Shock | Up to 8g ±3% |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C | Light | Measured in lumens |
GPS | Cellular tower connection enabling geolocation | Humidity | ±3% RH from 0 to 100% |
Temperature Range
NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
GPS
Cellular tower connection enabling geolocation
Barometric Pressure
300 – 1100 hPa (mbar)
Shock
Up to 8g ±3%
Light
Measured in lumens
Humidity
±3% RH from 0 to 100%
THP-GEOCell Sensor

Temperature Range | ± 1.0 °C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Humidity | ±3% RH from 0 to 100% |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C | GPS | Cellular tower connection enabling geolocation |
Temperature Range
± 1.0 °C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
GPS
GPS Cellular tower connection enabling geolocation
Barometric Pressure
300 – 1100 hPa (mbar)
Humidity
±3% RH from 0 to 100%
S-GPSCell Sensor

Temperature Range | NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Shock | Up to 8g ±3% |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C | Light | Measured in lumens |
GPS | Satellite connection | Humidity | ±3% RH from 0 to 100% |
Temperature Range
NIST Traceable ± 0.1°C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
GPS
Satellite connection enabling GPS
Barometric Pressure
300 – 1100 hPa (mbar)
Shock
Up to 8g ±3%
Light
Measured in lumens
Humidity
±3% RH from 0 to 100%
THP-GPSCell Sensor

Temperature Range | ± 1.0 °C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Humidity | ±3% RH from 0 to 100% |
Battery Life | Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C | GPS | Satellite connection |
Temperature Range
± 1.0 °C -40°C to +85°C (-40°F to +185°F)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Battery Life
Up to 60+ days running on Ni-MH plane-safe, rechargeable batteries at -20°C; up to 3 weeks at -40°C; up to 10 weeks at +20°C
GPS
Satellite connection enabling GPS
Barometric Pressure
300 – 1100 hPa (mbar)
Humidity
±3% RH from 0 to 100%
Warehouse Sensors
W-Sensors provide automated temperature, humidity and pressure monitoring of cold storage facilities with the Gateway infrastructure and Power-over-Ethernet connection.
W Sensor

Temperature Range | ± 1.0 °C -40°C to +85°C (-40°F to +185°F) | Barometric Pressure | 300 - 1100 hPa (mbar) |
Optional Range | T-Type thermocouple ±1°C for measuring -100°C to +100°C | Humidity | ±3% RH from 0 to 100% |
Battery Life | Power-over-Ethernet (no battery) |
Temperature Range
± 1.0 °C -40°C to +85°C (-40°F to +185°F)
Battery Life
Power-over-Ethernet (no battery)
Optional Range
T-Type thermocouple ±1°C for measuring -100°C to +100°C
Barometric Pressure
300 – 1100 hPa (mbar)
Humidity
±3% RH from 0 to 100%
Pick the Right Design for Your Use Case

ABS Plastic Case
IP65 Tested for durability
- 90x70x28 mm, 130 g (T-BLE)
- 135x70x26 mm, 145 g

Lightweight Paper Case
Lightweight design for global postal returns
- 110x65x13 mm, 55 g (T-BLE)
- 110x65x13 mm, 68 g

Truck Mountable Case
Designed to mount in trucks with access to vehicle power, with an internal battery backup
- 190x72x29 mm, 180 g

Extended Life Sensor Case
Durable ABS Case with additional batteries for longer shipping duration, ideal for sea freight
- 127x97x38 mm, 350 g
All ColdChase™ sensors are internationally compliant and approved by major airlines
Federal Communications Commission & I.C. Industry Canada
All ColdChase™ products comply with Canadian and U.S. government requirements for electronic products.
National Institute of Standards and Technology
ColdChase™ products contain NIST traceable sensors for accurate data recording.
21 CFR Part 11 Requirements for Electronic Records
ColdChase™ software complies with 21 CRF Part 11 requirements in creating and transmitting electronic records, ensuring authenticated, secured data that has been unaltered.
DO-160 Environmental Conditions and Test Procedures for Airborne Equipment
All ColdChase™ products have been tested and comply with the international avionic equipment standards DO-160G Category P and Q.